[{"data":1,"prerenderedAt":150},["ShallowReactive",2],{"zpl-documentation-caret-ma":3},{"guide":4,"previousGuide":136,"nextGuide":140,"coverage":144},{"canonical":5,"slug":6,"title":7,"summary":8,"reference":9,"category":10,"effect":11,"scope":12,"status":13,"limitations":14,"signatures":16,"searchText":135},"^MA","caret-ma","Set Maintenance Alerts","^MA configures set Maintenance Alerts. It applies to the printer session and subsequent formats and controls printer hardware or connectivity rather than label pixels.","https:\u002F\u002Fdocs.zebra.com\u002Fus\u002Fen\u002Fprinters\u002Fsoftware\u002Fzpl-pg\u002Fc-zpl-zpl-commands\u002Fr-zpl-ma.html","printer","device","session","non-rendering",[15],"Recognized by the renderer but has no label-raster effect.",[17],{"id":18,"syntax":19,"parameters":20,"examples":134},"caret-ma-signature-1","^MAtype,print,printlabel_threshold,frequency,units",[21,46,67,87,107],{"id":22,"key":23,"name":24,"description":25,"defaultValue":26,"choices":27,"enumValues":30,"required":31,"repeatable":31,"examples":32},"0-0-0-type","type","type of alert","Sets type of alert. It can be omitted when the documented default is suitable.","This parameter must be specified as R or C for print , printlabel_threshold , and frequency to be sa",[28,29],"R","C",[28,29],false,[33,40],{"id":34,"command":5,"signatureIndex":35,"parameterId":22,"title":36,"description":37,"value":28,"source":38,"filename":39,"cursorOffset":35,"preview":31},"caret-ma-0-0-0-type-1-r",0,"type = R","Uses R for type of alert while the other command values stay at representative defaults.","^MAR,N,R,0,I\n","caret-ma-type-1.zpl",{"id":41,"command":5,"signatureIndex":35,"parameterId":22,"title":42,"description":43,"value":29,"source":44,"filename":45,"cursorOffset":35,"preview":31},"caret-ma-0-0-0-type-2-c","type = C","Uses C for type of alert while the other command values stay at representative defaults.","^MAC,N,R,0,I\n","caret-ma-type-2.zpl",{"id":47,"key":48,"name":49,"description":50,"defaultValue":51,"choices":52,"enumValues":54,"required":31,"repeatable":31,"examples":55},"0-1-0-print","print","determines if the alert prints a label","Sets determines if the alert prints a label. It can be omitted when the documented default is suitable.","N",[51,53],"Y",[53,51],[56,62],{"id":57,"command":5,"signatureIndex":35,"parameterId":47,"title":58,"description":59,"value":53,"source":60,"filename":61,"cursorOffset":35,"preview":31},"caret-ma-0-1-0-print-1-y","print = Y","Uses Y for determines if the alert prints a label while the other command values stay at representative defaults.","^MAR,Y,R,0,I\n","caret-ma-print-1.zpl",{"id":63,"command":5,"signatureIndex":35,"parameterId":47,"title":64,"description":65,"value":51,"source":38,"filename":66,"cursorOffset":35,"preview":31},"caret-ma-0-1-0-print-2-n","print = N","Uses N for determines if the alert prints a label while the other command values stay at representative defaults.","caret-ma-print-2.zpl",{"id":68,"key":69,"name":70,"description":71,"defaultValue":72,"choices":73,"required":31,"repeatable":31,"examples":75},"0-2-0-printlabel-threshold","printlabel_threshold","the distance where the first alert occurs","Sets the distance where the first alert occurs. It can be omitted when the documented default is suitable.","R = 50 km (1,968,500 inches) and C = 0 (off)",[28,29,74],"0",[76,81],{"id":77,"command":5,"signatureIndex":35,"parameterId":68,"title":78,"description":79,"value":28,"source":38,"filename":80,"cursorOffset":35,"preview":31},"caret-ma-0-2-0-printlabel-threshold-1-r","printlabel_threshold = R","Uses R for the distance where the first alert occurs while the other command values stay at representative defaults.","caret-ma-printlabel-threshold-1.zpl",{"id":82,"command":5,"signatureIndex":35,"parameterId":68,"title":83,"description":84,"value":29,"source":85,"filename":86,"cursorOffset":35,"preview":31},"caret-ma-0-2-0-printlabel-threshold-2-c","printlabel_threshold = C","Uses C for the distance where the first alert occurs while the other command values stay at representative defaults.","^MAR,N,C,0,I\n","caret-ma-printlabel-threshold-2.zpl",{"id":88,"key":89,"name":90,"description":91,"defaultValue":92,"choices":93,"required":31,"repeatable":31,"examples":94},"0-3-0-frequency","frequency","distance before reissuing the alert","Sets distance before reissuing the alert. It can be omitted when the documented default is suitable.","0 (print on power-up)",[74],[95,100],{"id":96,"command":5,"signatureIndex":35,"parameterId":88,"title":97,"description":98,"value":74,"source":38,"filename":99,"cursorOffset":35,"preview":31},"caret-ma-0-3-0-frequency-1-0","frequency = 0","Uses 0 for distance before reissuing the alert while the other command values stay at representative defaults.","caret-ma-frequency-1.zpl",{"id":101,"command":5,"signatureIndex":35,"parameterId":88,"title":102,"description":103,"value":104,"source":105,"filename":106,"cursorOffset":35,"preview":31},"caret-ma-0-3-0-frequency-2-1","frequency = 1","Uses 1 for distance before reissuing the alert while the other command values stay at representative defaults.","1","^MAR,N,R,1,I\n","caret-ma-frequency-2.zpl",{"id":108,"key":109,"name":110,"description":111,"defaultValue":112,"choices":113,"enumValues":115,"required":31,"repeatable":31,"examples":116},"0-4-0-units","units","odometer and printhead maintenance commands","Sets odometer and printhead maintenance commands. It can be omitted when the documented default is suitable.","I",[112,29,114],"M",[29,112,114],[117,123,128],{"id":118,"command":5,"signatureIndex":35,"parameterId":108,"title":119,"description":120,"value":29,"source":121,"filename":122,"cursorOffset":35,"preview":31},"caret-ma-0-4-0-units-1-c","units = C","Uses C for odometer and printhead maintenance commands while the other command values stay at representative defaults.","^MAR,N,R,0,C\n","caret-ma-units-1.zpl",{"id":124,"command":5,"signatureIndex":35,"parameterId":108,"title":125,"description":126,"value":112,"source":38,"filename":127,"cursorOffset":35,"preview":31},"caret-ma-0-4-0-units-2-i","units = I","Uses I for odometer and printhead maintenance commands while the other command values stay at representative defaults.","caret-ma-units-2.zpl",{"id":129,"command":5,"signatureIndex":35,"parameterId":108,"title":130,"description":131,"value":114,"source":132,"filename":133,"cursorOffset":35,"preview":31},"caret-ma-0-4-0-units-3-m","units = M","Uses M for odometer and printhead maintenance commands while the other command values stay at representative defaults.","^MAR,N,R,0,M\n","caret-ma-units-3.zpl",[],"^ma set maintenance alerts ^ma configures set maintenance alerts. it applies to the printer session and subsequent formats and controls printer hardware or connectivity rather than label pixels. printer device session non-rendering type type of alert sets type of alert. it can be omitted when the documented default is suitable. print determines if the alert prints a label sets determines if the alert prints a label. it can be omitted when the documented default is suitable. printlabel_threshold the distance where the first alert occurs sets the distance where the first alert occurs. it can be omitted when the documented default is suitable. frequency distance before reissuing the alert sets distance before reissuing the alert. it can be omitted when the documented default is suitable. units odometer and printhead maintenance commands sets odometer and printhead maintenance commands. it can be omitted when the documented default is suitable.",{"canonical":137,"slug":138,"title":139},"^LT","caret-lt","Label Top",{"canonical":141,"slug":142,"title":143},"^MC","caret-mc","Map Clear",{"commands":145,"signatures":146,"parameters":147,"examples":148,"previewExamples":149},223,225,630,1552,722,1786111153438]