^SOSet Offset (for Real-Time Clock)
^SO configures set Offset (for Real-Time Clock). It applies to the printer session and subsequent formats and can change pixels in the rendered label.
aClock set
Sets clock set. It can be omitted when the documented default is suitable.
- Default
value must be specified- Required
- No
23a variations
Compare values side by side; other parameters remain at representative defaults.
a = 2
Uses 2 for clock set while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZa = 3
Uses 3 for clock set while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO3,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZbMonths offset
Sets months offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000b variations
Compare values side by side; other parameters remain at representative defaults.
b = 0
Uses 0 for months offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZb = 1
Uses 1 for months offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,1,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZcDays offset
Sets days offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000c variations
Compare values side by side; other parameters remain at representative defaults.
c = 0
Uses 0 for days offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZc = 1
Uses 1 for days offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,1,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZdYears offset
Sets years offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000d variations
Compare values side by side; other parameters remain at representative defaults.
d = 0
Uses 0 for years offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZd = 1
Uses 1 for years offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,1,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZeHours offset
Sets hours offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000e variations
Compare values side by side; other parameters remain at representative defaults.
e = 0
Uses 0 for hours offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZe = 1
Uses 1 for hours offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,1,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZfMinutes offset
Sets minutes offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000f variations
Compare values side by side; other parameters remain at representative defaults.
f = 0
Uses 0 for minutes offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZf = 1
Uses 1 for minutes offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,1,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZgSeconds offset
Sets seconds offset. It can be omitted when the documented default is suitable.
- Default
0- Range
-32000–32000- Required
- No
032000g variations
Compare values side by side; other parameters remain at representative defaults.
g = 0
Uses 0 for seconds offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,0
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZg = 1
Uses 1 for seconds offset while the other command values stay at representative defaults.
^XA
^PW640
^LL360
^SO2,0,0,0,0,0,1
^FO48,95^A0N,42,38^FDText command example^FS
^FO28,318^A0N,22,22^FDCaret SO parameter example^FS
^XZPrimary source
Official Zebra reference
Use the manufacturer reference for printer- and firmware-specific behavior beyond ZPLr’s pinned rendering profile.